46
SET-UP PROCEDURES FOR ULV OPERATIONS
To conduct ULV operations, you must purchase a special
ULV nozzle system. The system is no longer available in
the National Stock System (no current NSN), but may still
be encountered during deployments.
2. a. Set up the unit into the mist spray configuration
as described above.
b. Remove the mist spray nozzle and replace it with
the ULV nozzle.
c. Remove the ULV pesticide container and ensure
that the gasket, located inside of the housing, is
in place.
d. Ensure that the ULV pesticide volume control
knob is in the OFF position.
e. If the operation will require a large amount of
ULV solution, remove small bottle from under
nozzle, disconnect pickup tube and screen, and
reinstall tubing from tank to under volume control
cock. Then connect the mist spray pesticide line,
and conduct the operation in the same manner
as a mist spray.