 9. To stop the engine, lift the control knob to the “off”
position.
FOGGING
 10. Verify that the formulation and fuel tank caps are
tight.
 11. Start engine as specified in the above section.
 12. Allow engine 1-2 minutes running time to warm up
to operating temperature.
 13. Set formulation-metering valve (flow rate) to
desired fog quality.
 14. Push formulation valve button (thumb trigger) to
fog.
 15. Close metering valve immediately after fogging;
allow any pesticide remaining in lines to flush,
before shutting engine off.
MAINTENANCE
 16. After each use, drain any unused formulation from
the tank into its original container for proper
storage by removing 7/16” plug at bottom of the
formulation tank.
 17. Flush out machine with approved flushing solvent
after draining out formulation tank.