132
 11. The Engine Speed Control Slide Ring is located
under the Air Filter Housing on the left side of
engine. Pull ring halfway out.
 12. Ensure all Remote Control switches are in the
“OFF” position.
 13. Plug one end of the Remote Control Cable into the
back side of the Pump Assembly.
 14. Plug the other end of the Remote Control Cable
into the base of the Remote Control Box.
 15. a. The Starter Solenoid Switch is located on the
right side of the engine. Place it into the ON
position.
 b. Place the Machine Switch on the Control Box
into the “On” position.
 c. Push the Start Switch on the Control Box for a
maximum of 15 seconds. CAUTION: HEARING
PROTECTION REQUIRED. Note: optional
Starter Button located on the right side of the
Engine Air Filter can also be used.
 16. Engine starts.
 17. The Boom Pressure Gauge is located between the
Engine and the Blower. Pressure should read 6
psi. (pressure may vary slightly due to viscosity of
formulation)
Przeglądanie stron 139