7
7. Check for proper pressurization and the possibility
of leaks in the system by adding water to the tank.
Leave approximately 1/3 of the tank empty for an
air gap.
8. Replace the rod/piston assembly cylinder back into
the tank.
9. To properly pressurize the tank, pump the unit 6-10
times. Depress the trigger on the wand. Check for
water and air leaks in the hose, tubing, wand and
tank seals. Repair all leaks.
10. Discontinue spraying the water and slowly relieve
the tank pressure by turning knurled nut
counterclockwise where hose connects to the top
of the tank.
11. Remove the pump assembly and dump out the
water.
OPERATING PROCEDURES
12. Put on all personal protective gear.
13. Calculate the exact amount of pesticide needed for
the operation.
14. Add the calculated amount of carrier first and then
add the pesticide through a 60-mesh screen filter,
to bring the solution up to the label's
recommendation.