26. Place the Output Switch on the Remote Control
Box in the “OFF” Position.
27. Turn all switches on the Remote Control Box to
“OFF” position. (i.e. Machine and Output)
CALIBRATION PROCEDURES
28. For ULV calibration, carry out steps 1-22.
29. Place Function Selector Dial in the #2 position.
Adjust flow rate to desired flow (4 oz, 6 oz, 8 oz,
etc.).
30. Place Solenoid Switch on Remote Control Box to
“SPRAY” position.
31. Place HIGH/LOW Selector Switch in the “HIGH”
position.
32. Disconnect ¼ inch formulation line from the “T” on
the Spray Boom and place into a “pesticide only”
receptacle. Always use a suitable collection
container for pesticide measurement.
33. Place the Output Switch on the Remote Control in
the “ON” position (fluid will begin to flow).
34. Adjust the Flow Rate Knob on the Remote Control
Box to the desired rate.
35. The timing person signals the beginning and the
end of the one (1) minute collection period.