 30. The rate of vehicle speed during the spray
operation is generally 5 or 10 mph. The correct
speed for each type of pesticide is indicated on the
pesticide label.
 31. When stopping for a short period of time, turn the
remote control output switch to the OFF position.
TERMINATING PROCEDURES
 32. After completing your spray operation, with the
engine still running, turn the formulation selector
valve, located below the flushing solution tank, to
the "FLUSH" position.
 33. Place the switch on the remote control in the
"FLUSH" position.
 34. Place the output switch on the remote control in
the "ON" position.
 35. Set the flow rate on the remote control digital read-
out to 10 oz/min and flush system for 2-3 min.
 36. Turn all switches to the "OFF" position (Ignition,
formulation valve, and remote control switches).
CALIBRATION PROCEDURES
 37. For ULV calibration, carry out steps 1-22.
 38. Move the formulation selector valve, located below
the solution tank, to the "SPRAY" position.